Put a vertical load on top of a retaining wall (a beam, a deck ledger, a column bearing on the stem) and the stem stops being a simple cantilever. It becomes a lightly loaded column: it still bends under the soil pressure, but it also carries axial compression. RetainX checks the stem for that combination and draws the result as an interaction diagram on the Diagrams tab. This article explains how to read that chart, how RetainX builds it, and what each related warning means.
When does RetainX check the stem for axial load?
RetainX runs the combined check when the factored axial load on the stem is more than 100 lb per foot of wall (about 1.46 kN/m). That load includes the stem's own weight, so in practice every stem gets the combined check. The factored load is the larger of \(1.4D\) and \(1.2D + 1.6L\) (ASCE 7-16 §2.3.2), where \(D\) is the vertical dead load plus the stem's weight above the section and \(L\) is the vertical live load.
The check is made at the base of the stem. On a two-segment wall, it is also made at the base of the top segment. When it runs, the Diagrams tab dropdown lists Interaction - Stem Base (and Interaction - Stem Top on a two-segment wall) at the top, followed by the familiar Moment and Shear graphs.
How do I read the interaction chart?
A 16 ft wall with a 12 in. stem, #8 bars at 6 in., f'c = 3,000 psi and Grade 60 steel, carrying 300 lb/ft dead and 600 lb/ft live load.
- Green area (capacity envelope): every combination of design axial strength \(\phi P_n\) and design moment strength \(\phi M_n\) the stem section can carry.
- Red dot (demand): the factored axial load \(P_u\) and factored moment \(M_u\) at the section. When the stem is slender, \(M_u\) includes the moment magnification from the Slender Wall check in the report.
- Red dashed line: runs from the origin through the demand, at a constant eccentricity \(e = M_u / P_u\). RetainX assumes the axial load and moment grow together, so the stem's capacity is where this line leaves the usable envelope.
- Gray dashed vertical line (App's capacity cap): explained in the next section.
If the red dot sits inside the green area and to the left of the gray dashed line, the stem passes the combined check. In the example above, the capacity along the dashed line is \(\phi P_n\) = 1,985 lb and \(\phi M_n\) = 55,052 lb-ft, against a demand of 1,320 lb and 36,596 lb-ft, a ratio of 0.66.
What is the "App's capacity cap" line?
The gray dashed line sits at the stem's pure-bending design strength, \(\phi M_n\), which is the same capacity the Moment graph shows. RetainX never lets the stem's moment capacity exceed that value, even when axial load is present.
Axial compression can raise a section's moment capacity. On a lightly reinforced stem, you can see this as the curve bulging out to the right of the line as the axial load increases. RetainX deliberately doesn't use that extra capacity. That's conservative, and it keeps the combined check consistent with the bending check you see on the Moment graph. The usable envelope is the green area to the left of the gray dashed line.
Why does pure bending match the Moment graph?
Where the curve meets the moment axis (zero axial load), the stem is in pure bending, so the interaction chart and the Moment graph should give the same capacity, and they do.
The Moment graph for the same wall. The capacity line sits at about 55,600 lb-ft.
For this wall, both charts give 55,564 lb-ft. The calculation behind that number:
- Depth of the compression block: \(a = A_s f_y / (0.85 f'_c b)\) = 3.10 in.
- Neutral axis depth: \(c = a / \beta_1\) = 3.65 in., so \(c/d\) = 0.384 with \(d\) = 9.5 in.
- Nominal moment strength: \(M_n\) = 62,815 lb-ft.
- Net tensile strain in the steel: \(\varepsilon_t\) = 0.0048, just short of the 0.005 tension-controlled limit, so \(\phi\) = 0.885 from the transition equation below.
- Design strength: \(\phi M_n\) = 0.885 × 62,815 = 55,564 lb-ft.
A note on earlier versions
Earlier versions of RetainX drew this same wall's curve starting at about 41,000 lb-ft, well short of the Moment graph's 55,600. They used a simplified strength reduction factor that jumped straight from 0.90 to 0.65 once \(c/d\) passed 0.375, with no transition zone in between. This wall's \(c/d\) of 0.384 is just past that cutoff, so it was assigned 0.65 instead of 0.885. Current versions use ACI's transition equation, so the two charts agree.
How is the curve calculated?
RetainX builds the curve by strain compatibility, the same way a hand calculation would:
- The concrete strain at the compression face is 0.003. RetainX steps the neutral axis depth \(c\) from near zero to beyond the full stem thickness.
- For each \(c\), it finds the concrete compression block (depth \(a = \beta_1 c\)) and the strain and stress in the vertical bars (stress capped at \(f_y\)). From those it calculates the nominal axial strength \(P_n\) and moment strength \(M_n\).
- It multiplies both by the strength reduction factor \(\phi\) for that steel strain, which gives one point on the curve.
A few modelling choices are specific to wall stems:
- One layer of steel: the stem's vertical bars, at the effective depth \(d\). When those bars end up on the compression side, their contribution is ignored.
- \(\beta_1\): per ACI 318 Table 22.2.2.4.3. It is 0.85 up to f'c = 4,000 psi, then drops 0.05 for each 1,000 psi, to a minimum of 0.65.
- Flat top: the axial strength is capped at \(0.80\,\phi P_0\), ACI 318's maximum axial strength for members without spirals (22.4.2.1). RetainX takes \(P_0 = 0.85 f'_c (A_g - A_{st})\), leaving out the bars' own contribution \(f_y A_{st}\), which is conservative.
The strength reduction factor \(\phi\) follows ACI 318 Table 21.2.2, using the column for members without spiral reinforcement. It depends on the net tensile strain \(\varepsilon_t\) in the bars, where \(\varepsilon_{ty} = f_y / E_s\) (0.00207 for Grade 60 steel):
- Tension-controlled (\(\varepsilon_t \ge 0.005\)): \(\phi\) = 0.90
- Transition (\(\varepsilon_{ty} < \varepsilon_t < 0.005\)): \(\phi = 0.65 + 0.25\,\dfrac{\varepsilon_t - \varepsilon_{ty}}{0.005 - \varepsilon_{ty}}\)
- Compression-controlled (\(\varepsilon_t \le \varepsilon_{ty}\)): \(\phi\) = 0.65
The same \(\phi\) and \(\beta_1\) are used in the stem's bending check, which is why the two agree in pure bending.
Why does the curve have sharp corners?
Textbook interaction diagrams usually show the design strength as a smooth curve inside the nominal strength curve. RetainX's chart shows only the design strength, and it can have a sharp point and a notch. Both are real features of ACI's \(\phi\) rule, not drawing errors.
Nominal strength (gray) and design strength (green) for an 8 in. stem with #4 bars at 12 in. The design curve's two corners are where \(\phi\) starts and stops changing.
Multiplying by \(\phi\) scales each point of the nominal curve toward the origin. While \(\phi\) is constant, the design curve has the same smooth shape as the nominal curve. The corners come from the two places where \(\phi\) changes how it behaves:
- At \(\varepsilon_t\) = 0.005, \(\phi\) starts falling from 0.90. On this stem that is at about 14,500 lb-ft and 40,000 lb, the outermost point of the curve.
- At \(\varepsilon_t = \varepsilon_{ty}\) (the balanced point), \(\phi\) stops falling and stays at 0.65. That is at about 13,400 lb-ft and 50,000 lb.
Between those two points, \(\phi\) is dropping faster than the nominal strength is growing, so the design curve turns back in. Above the balanced point, \(\phi\) is constant again and the curve bulges back out with the nominal curve.
The same stem as RetainX draws it. The corners sit to the right of the capacity cap, so they don't affect the check.
Two other differences from a textbook figure are worth knowing:
- Textbook figures are usually drawn for a column with bars on both faces. A wall stem has one layer of bars, so between pure bending and \(\varepsilon_t\) = 0.005 (where the steel yields and \(\phi\) is constant at 0.90), the curve is nearly a straight line.
- A heavily reinforced stem, like the 12 in. stem with #8 bars at 6 in. above, is already in the transition zone in pure bending. Its curve starts on the moment axis and slopes up and to the left, because adding axial load lowers \(\phi\) faster than it adds strength.
What warnings does RetainX show?
RetainX measures both the axial ratio \(P_u/\phi P_n\) and the moment ratio \(M_u/\phi M_n\) at the point where the red dashed line leaves the usable envelope. That point is on the curve, on the flat top, or on the capacity cap line, whichever the line reaches first. Because both ratios are measured at the same point, they always agree: either both are under 1.0 or both are over. The axial ratio is listed on the Elements tab, under Base Stem (and Top of Stem).
Demand outside the envelope
The same 16 ft wall with 8,000 lb/ft dead and 8,000 lb/ft live load. The demand (22,400 lb, 52,183 lb-ft) is past the curve; the capacity on the dashed line is 21,430 lb and 49,941 lb-ft, a ratio of 1.05.
Two warnings appear in the results bar:
- Base of Stem: \(P_u > \Phi P_n\) under Design Issues. This becomes Top of Stem when the top segment of a two-segment wall fails.
- \(M_u / \Phi M_n > 1.0\) under Stem (\(M_{u,Top} / \Phi M_{n,Top} > 1.0\) for the top segment).
Both warnings link to this article whenever the combined check has run.
Demand right of the capacity cap
An 8 ft wall with an 8 in. stem and #4 bars at 12 in., carrying 12,000 lb/ft dead and 8,000 lb/ft live load.
Here the demand (27,200 lb, 5,490 lb-ft) sits inside the curve but to the right of the capacity cap at 4,999 lb-ft. RetainX treats this as a failure, because the usable envelope stops at the cap. The capacity is taken where the dashed line crosses the cap: 24,772 lb and 4,999 lb-ft. That gives an axial ratio of 1.10, and the same two warnings appear.
Stem buckling: \(P_u \ge 0.75 P_c\)
When the stem is slender, RetainX magnifies the moment using ACI 318's moment magnification method (6.6.4.5.2):
\[ \delta = \frac{C_m}{1 - \dfrac{P_u}{0.75\,P_c}} \]
Here \(P_c\) is the stem's critical buckling load. As \(P_u\) approaches \(0.75 P_c\), \(\delta\) grows without limit. At or beyond it, the formula has no meaningful answer, because the stem would buckle under the axial load alone. RetainX then shows Base of Stem: \(P_u \ge 0.75 P_c\) (Buckling Limit) (or Top of Stem) alongside the other two warnings.
In this case, the magnified moment in the report and on the chart is not a real demand, so don't read anything into its size. The fix is a stiffer or shorter stem: increase the stem thickness, reduce the stem height, or reduce the vertical load.
Should I still use the Moment graph when there's axial load?
The Moment graph plots the bending demand down the height of the stem against its bending capacity. It ignores axial load, so with axial load on, the interaction chart is the one that governs. Its red dot includes both the axial load and any slenderness magnification.
The two demands are usually close. For example, on an 8 in. stem with 300 lb/ft dead and 600 lb/ft live load, the Moment graph's base moment is 2,304 lb-ft and the interaction chart's demand is 2,322 lb-ft. The Moment graph stays in the dropdown when there's axial load because it shows where along the stem the moment builds up, which the interaction chart doesn't.
References
- ACI 318-19, Building Code Requirements for Structural Concrete: Table 21.2.2 (strength reduction factors), 22.2.2.4.3 (\(\beta_1\)), 22.4.2.1 (maximum axial strength), 6.6.4.5.2 (moment magnification).
- Reinforced concrete design texts cover interaction diagrams and ACI's safety provisions in their short-column chapters.