When RetainX shows Resultant Outside Middle Third, the heel of the footing is lifting off the soil. Here's what that means and how to fix it.
What the "resultant" is
Everything acting on the wall adds up to one combined force pushing down into the soil under the footing:
- the weight of the wall and footing
- the weight of the soil sitting on the heel
- the soil pushing sideways on the stem
That single combined force is the resultant. Where it lands under the footing tells you how the footing is sitting on the ground.
What the middle third is
Split the footing's width into three equal parts. The middle third is the center part. For a footing B feet wide, it runs from B/3 to 2B/3, measured from the front of the toe.
- Resultant inside the middle third: the whole bottom of the footing presses on the soil. The pressure is higher under the toe than under the heel, but every part of the footing is in contact.
- Resultant right on the edge (B/3): the pressure under the heel drops to exactly zero.
- Resultant outside, toward the toe: the heel no longer presses on the soil at all. It lifts off.
In engineering terms, the distance from the center of the footing to the resultant is the eccentricity \(e\), and the check is:
\[ e \le \frac{B}{6} \]
Why heel uplift is a problem
Soil can push up on a footing, but it can't pull down on it. Once the resultant leaves the middle third:
- The heel lifts. Part of the footing is carrying nothing.
- The pressure piles up under the toe. The same load is now carried by a smaller strip of soil, so the bearing pressure at the toe jumps.
- The wall leans forward. The toe settles more than the heel, so the wall rotates outward. That shows up as a wall that tips out of plumb over time, cracks, and gaps opening behind the heel.
This can happen even when the overturning safety factor passes. That's why RetainX checks the middle third separately.
An example
A two-segment wall retaining 10.5 ft of soil, with a 7.5 ft wide footing (2.5 ft toe, 1 ft stem, 4 ft heel), with seismic load. The middle third starts 2.5 ft from the front of the toe. RetainX puts the resultant at 1.71 ft, outside the middle third, and the pressure under the heel is zero: the heel has lifted.
- 4 ft heel (the start): the resultant is 1.71 ft from the toe, but the middle third starts at 2.50 ft. Heel pressure is 0 psf: lifted. Fails.
- 5 ft heel: the resultant moves to 2.58 ft, but the middle third now starts at 2.83 ft. The heel is still lifted. Fails.
- 6 ft heel: the resultant moves to 3.34 ft, inside the middle third, which starts at 3.17 ft. The heel presses down with 141 psf. Passes.
How to fix it
- Lengthen the heel. This is usually the best fix. A longer heel carries more soil weight behind the stem, which pulls the resultant back toward the center, and it widens the footing at the same time.
- Widen the footing overall. A wider footing means a wider middle third.
- Reduce the push on the wall. Good drainage behind the wall (gravel and a drain, so water can't build up), free-draining granular backfill, and keeping heavy loads back from the top of the wall all reduce the sideways force.
A shear key under the footing does not help here. It resists sliding, not uplift.
Static and seismic
RetainX checks the middle third for the normal (static) loads and, when seismic is on, for the loads with the seismic force included. Design Issues tells you which one failed: "Resultant Outside Middle Third" or "Resultant (with Seismic Force) Outside Middle Third". The fixes are the same either way.