RetainX Notes / Design fundamentals
Design fundamentals

Why the Resultant Must Stay in the Middle Third

When RetainX shows Resultant Outside Middle Third, the heel of the footing is lifting off the soil. Here's what that means and how to fix it.

What the "resultant" is

Everything acting on the wall adds up to one combined force pushing down into the soil under the footing:

That single combined force is the resultant. Where it lands under the footing tells you how the footing is sitting on the ground.

What the middle third is

Split the footing's width into three equal parts. The middle third is the center part. For a footing B feet wide, it runs from B/3 to 2B/3, measured from the front of the toe.

In engineering terms, the distance from the center of the footing to the resultant is the eccentricity \(e\), and the check is:

\[ e \le \frac{B}{6} \]

Why heel uplift is a problem

Soil can push up on a footing, but it can't pull down on it. Once the resultant leaves the middle third:

This can happen even when the overturning safety factor passes. That's why RetainX checks the middle third separately.

An example

A two-segment wall retaining 10.5 ft of soil, with a 7.5 ft wide footing (2.5 ft toe, 1 ft stem, 4 ft heel), with seismic load. The middle third starts 2.5 ft from the front of the toe. RetainX puts the resultant at 1.71 ft, outside the middle third, and the pressure under the heel is zero: the heel has lifted.

How to fix it

A shear key under the footing does not help here. It resists sliding, not uplift.

Static and seismic

RetainX checks the middle third for the normal (static) loads and, when seismic is on, for the loads with the seismic force included. Design Issues tells you which one failed: "Resultant Outside Middle Third" or "Resultant (with Seismic Force) Outside Middle Third". The fixes are the same either way.


Up next
Why a Retaining Wall Stem Fails in Bending and How to Fix It →